Arq. bras. oftalmol ; 86(6): e2021, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520198

ABSTRACT

ABSTRACT Purpose: Since particles are released in syringes during intravitreal injections, we assessed them quantitatively after agitating syringes commonly used for intravitreal injections. Methods: With and without agitation, the SR 1-ml insulin, Becton-Dickinson Ultra-Fine 0.3-ml Short Needle with a half-unit scale, HSW Norm-Ject Tuberculin, and Becton-Di­ckinson 1-ml Luer Lok Tip were examined with buffer and bevacizumab, aflibercept, and ziv-aflibercept. Flow imaging microscopy was performed to assess the particle numbers, concentrations, morphology, and size distribution. Results: Using the Becton-Dickinson Ultra-Fine syringe, the average particle count after agitation was higher than in the no-agitation group. For particles greater than 10 and 25 µm, differences were observed using the SR syringe between the two studied conditions. There were no significant differences in the means for the other syringes. Without agitation, the SR syringe had the highest number of particles (2,417,361.7 ± 3,421,575.5) followed by the Becton-Dickinson Ultra-Fine with 812.530,9 ± 996.187,2. The Becton-Dickinson Luer Lok Tip and HSW Norm-Ject performed equally with 398,396.8 ± 484,239.2 and 416,016.4 ± 242,650.1 particles, respectively. Conclusions: Flicking syringes to eliminate air bubbles results in increased numbers of particles released during intravitreal injections into the human vitreous.


RESUMO Objetivo: Visto que partículas são liberadas nas seringas durante as injeções intravítreas (IVIs), estas foram avaliadas quantitativamente após a agitação das seringas mais comumente usadas para injeções intravítreas. Métodos: A seringa SR de 1 ml de insulina, a agulha curta Becton-Dickinson Ultra-Fine 0,3 ml com escala de meia unidade, HSW Norm-Ject Tuberculin e a Becton-Dickinson Luer Lok Tip de 1 ml foram estudadas com placedo e com bevacizumabe, aflibercept e ziv-aflibercept, com e sem agitação. MicroFlow Imaging Mi­croscopy foi realizada para avaliar o número de partículas, con­centração, morfologia e distribuição das mesmas por tamanho. Resultados: A contagem média de partículas após agitação foi maior do que no grupo sem agitação usando a seringa Becton-Di­ckinson Ultra-Fine. Diferenças foram observadas usando a seringa SR entre as duas condições estudadas para partículas maiores que 10 e 25 µm. Para as demais seringas, não foram observadas diferenças significativas nas médias. A seringa SR apresentou o maior número de partículas sem agitação (2.417.361,7 ± 3.421.575,5) seguida da Becton-Dickinson Ultra-Fine com 812.530,9 ± 996.187,2. A BD Luer Lok Tip e a HSW Norm-Ject se comportaram de forma semelhante com 398.396,8 ± 484.239,2 e 416.016,4 ± 242.650,1 partículas, respectivamente. Conclusões: Agitar seringas para remover bolhas de ar resulta em um maior número de partículas liberadas durante Becton-Dickinson no vítreo humano.

3.
Arq. bras. oftalmol ; 77(1): 1-3, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-715558

ABSTRACT

Purpose: To analyze the corneal thickness and anterior chamber (AC) angle using anterior segment optical coherence tomography (AS-OCT) in patients with acute anterior uveitis (AAU). Methods: Twenty two patients (24 eyes) were included. All patients underwent complete ophthalmological examination, applanation tonometry and AS-OCT at diagnosis and fifteen days after treatment. Results: Average corneal thickness before treatment was 564.2 ± 44.2 µm, 580.0 ± 44.3 µm and 580.1 ± 2.9 µm, respectively in central, pericentral and paracentral cornea. Fifteen days after treatment a significant decrease of corneal thickness was observed, with 529.5 ± 33.1 µm (p=0.0091) and 542.6 ± 33.6 µm (p=0.0068), respectively in central and pericentral cornea; paracentral corneal thickness (557.8 ± 35.3 µm) thinning did not reach statistical significance (p=0.1253). There was no significant change in temporal AC angle between visits, 44.3 ± 14.4 degrees before treatment and 44.7 ± 14.7 degrees fifteen days after (p=0.9343), and mean intraocular pressure, 10.8 ± 4.5 mmHg before treatment and 12.3 ± 3.0 mmHg fifteen days after (p=0.1874). Conclusion: In the studied group, AS-OCT detected a decrease of corneal thickness after AAU treatment. Temporal AC angle and intraocular pressure did not change during the studied period. .


Objetivo: Analisar a espessura corneal e ângulo da câmara anterior (CA) utilizando a tomografia de coerência óptica de segmento anterior (OCT-SA) em pacientes com uveíte anterior aguda (UAA). Métodos: Foram selecionados 24 olhos de 22 pacientes com UAA. Todos foram submetidos a exame oftalmológico completo, tonometria de aplanação e OCT-SA na consulta inicial e após 15 dias de início do tratamento. Resultados: Na visita inicial, as médias da espessura corneal foram de 564,2 ± 44,2 µm e 580,0 ± 44,3 µm e 580,1 ± 2,9 µm, respectivamente para as regiões central, pericentral e paracentral. Após 15 dias de tratamento, observou-se redução da espessura para 529,5 ± 33,1 µm (p=0,0091) e 542,6 ± 33,6 µm (p=0,0068), respectivamente para a córnea central e pericentral; e um valor de 557,8 ± 35,3 µm para a região paracentral, porém para um p não significante (p=0,1253). Não foi observada mudança estatisticamente significante nos valores da porção temporal do ângulo da CA; 44,3 ± 14,4 graus na visita inicial e de 44,7 ± 14,7 graus após 15 dias de tratamento (p=0,9343) e na média das pressões intraoculares (PIO), 10,8 ± 4,5 mmHg na visita inicial e 12,3 ± 3,0 mmHg após tratamento (p=0,1874). Conclusão: No grupo estudado, obteve-se uma redução dos valores da espessura corneal após início do tratamento da UAA. Os valores da porção temporal do ângulo da CA e PIO não sofreram mudanças significantes. .


Subject(s)
Adolescent , Adult , Aged , Child , Female , Humans , Male , Middle Aged , Young Adult , Anterior Eye Segment/pathology , Tomography, Optical Coherence/methods , Uveitis, Anterior/diagnosis , Acute Disease , Corneal Topography , Prospective Studies , Tonometry, Ocular , Uveitis, Anterior/surgery